General Notes; Safety; Identification Obligation; Installation Conditions - Graf HERKULES Notice D'installation Et D'entretien

Masquer les pouces Voir aussi pour HERKULES:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.1

Safety

The relevant accident prevention regulations according to BGV C22 have to be observed when
conducting any works. Especially when inspecting tanks a second person is required for safety reasons.
Furthermore, the relevant regulations and standards have to be observed during installation, assembly,
maintenance, repair, etc. You will find information about this in the related sections of these instructions.
During all works on the system respectively on system components the overall system has to be
decommissioned and secured against unintentional restart at all times.
The tank cover has to be closed at all times, except when conducting works on the tank, otherwise there
is a very high risk of accident. Only original GRAF covers or covers approved by the company GRAF in
writing are to be used.
The company GRAF offers a comprehensive portfolio of accessories that are aligned with each other and
can be developed into complete systems. Using deviating accessories can lead to impairments of the
functionality of the system and thus to the liability for damages resulting thereof expiring.
1.2

Identification obligation

All lines and tapping points of process water have to be labelled with the words "No drinking water" in
writing or visually (DIN 1988 part 2, section 3.3.2.) in order to avoid an accidental connection to the
drinking water network even after years. Even when there are correct labels, irritations are possible, e.g.
through children. That is why all tapping points of process water have to be installed with child-proof
valves.
2.1

Overground assembly

The tanks have to be installed on firm and level ground without sharp stones and without incline
Please observe the weight of the filled tank during assembly (1,650 kg)
In case of risk of frost, the tanks have to be emptied completely
When installing the tanks in closed rooms there has to be a floor drain
Children need supervision when lingering near the tanks
The tank must not be pressurised (water column)
2.2

Underground installation

By using the supporting tube (Order No. 322014) the tank may be installed under ground
(max. height above ground 1000 mm)
The tank head (Order No. 322026) has to be installed for possible revision works
In case of ground water and hillside situation special installation provision have to be observed
The tanks must only be installed in non-accessible green areas
Along with the earth load no additional loads must affect the tank in any case, the distance to the
accessible areas has to be at least 2.6 m
The tank must not be pressurised (water column)
mail@graf.info
www.graf.info
1.

General notes

2.

Installation conditions

9 / 35

Publicité

Table des Matières
loading

Table des Matières