1.8
ambient conditions
Min. operating temperature
Nom. operating temperature
Max. operating temperature
Max. relative humidity
2

pRODucT DEScRipTiON

2.1
components
The fan consists of the following main components:
Fig. 2.1
A
outlet
B
motor
C
housing
D inlet
E
fan wheel
A
B
Fig. 2.1
Main components
2.2
Operation
The extraction fan is a radial fan. The inlet at the back of the
fan is to be connected to the outlet of a central extraction
system. The extracted air is blown out at the side of the fan
through a duct. Depending on the local regulations, the air can
either be recirculated or exhausted to the atmosphere.
There are various options to control the fan.
2.2.1
Control equipment
Plymovent provides control equipment for controlling the fan.
Refer to the manual of the selected control equipment.
0000100437/010812/0 TEV-RANGE
5°C (41°F)
20°C (68°F)
40°C (104°F)
80%
C
D
E
3

SaFETy

general
The manufacturer does not accept any liability for damage to
the product or personal injury caused by ignoring of the safety
instructions in this manual, or by negligence during
installation, use, maintenance, and repair of the product
mentioned on the cover of this document and any
corresponding accessories. Specific working conditions or used
accessories may require additional safety instructions.
Immediately contact your supplier if you detect a potential
danger when using the product.
The user of the product is always fully responsible for
observing the local safety instructions and regulations.
user manual
- Everyone working on or with the product must be familiar
with the contents of this manual and must strictly observe
the instructions therein. The management should instruct the
personnel in accordance with the manual and observe all
instructions and directions given.
- Never change the order of the steps to perform.
- Always keep the manual with the product.
pictograms and instructions on the product
(if present)
- The pictograms, warning and instructions attached to the
product are part of the safety features. They must not be
covered or removed and must be present and legible during
the entire life of the product.
- Immediately replace or repair damaged or illegible
pictograms, warnings and instructions.
users
The use of this product is exclusively reserved to authorised,
well-trained and qualified users. Temporary personnel and
personnel in training can only use the product under
supervision and responsibility of skilled engineers.
intended use
1
The product has been designed as an extraction fan for
extracting fumes and gases which are released during the
most common welding processes, as well as the extraction of
exhaust gases. Using the product for other purposes is
considered contrary to its intended use. The manufacturer
accepts no liability for any damage or injury resulting from
such use. The product has been built in accordance with
state-of-the-art standards and recognised safety regulations.
Only use this product when in technically perfect condition in
accordance with its intended use and the instructions
explained in the user manual.
Technical specifications
The specifications given in this manual must not be altered.
Modifications
Modification of (parts of) the product is not allowed.
1. "Intended use" as explained in EN-ISO 12100 is the use for which the technical
product is suited as specified by the manufacturer, inclusive of his directions in
the sales brochure. In case of doubt it is the use which can be deduced from
the construction, the model and the function of the technical product which is
considered normal use. Operating the machine within the limits of its intended
use also involves observing the instructions in the user manual.