7.2.2
Mounting the filter insert
7.2.3
Replacing the burner hoses
Verify that the return line and the float chamber are completely drained
prior to replacing the burner hoses.
1. Drain the filter cup (see chapter "Replacing the filter insert").
2. Open the bypass valve with an Allan key (size 3).
- The liquid fuel is drained from the float chamber into the filter cup and
via the drain valve.
3. Replace the burner hoses.
4. Close the bypass valve and the drain valve.
Maintenance
FloCo-Top-2
EN
23