Factory Setting - Centronic SunWindControl SWC241 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wind threshold control switch
This control switch allows you to set the wind threshold values (approx. 2m/s
to 22 m/s).
The wind threshold value can be set to 11 different levels. If you turn the control
switch slowly, the tubular drive makes a clacking sound for each level.
- Left limit stop = Level 1: retract when wind speed is low
+ Right limit stop = Level 11: retract when wind speed is high
If the threshold values are changed, these are adopted immediately.
Note
Please ensure that no buttons are pressed when setting the threshold
value.
If the wind speed rises above the preset wind threshold, the sun protec-
tion system is retracted and remains closed. The sun protection sys-
tem is extended again if the wind speed remains below the preset wind
threshold for approx. 15 minutes.
TEST mode
The test mode will be activated by setting the threshold. This mode will auto-
matically be terminated after 15 minutes. The duration of the wind surveillance
will be reduced during test mode.
Wind threshold value: Left limit stop (2 m/s) Intermediate position

Factory setting