Hague Quality Water MicroBoss II Manuel Du Propriétaire Et Manuel D'installation page 36

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting, Cont.
Problem
Appliance stays in
regeneration.
Excess water in brine
cabinet
Not regenerating in
proper sequence
Salty water
Model 410 Owner's Manual
Possible Cause
Controller not attached properly
Foreign object in valve body
Broken valve assembly. Motor running
Restricted, frozen, or pinched drain line
Plugged brine line, brine line flow control, or
air check/draw tube
Plugged injector assembly
Sticking brine refill valve
Magnet disk defective
Defective controller
Plugged injector
Low water pressure
Drain line or flow control is restricted
Brine line restricted or crimped
Excessive amount of water in brine cabinet
Insufficient rinse time
Intermittent pressure drop from feed source
Brine valve drips water back to brine cabinet
Make sure the controller is pushed all the way
onto the drive end cap
Remove foreign object(s) from the valve body
Repair the drive end cap
Remove restriction, thaw, or straighten drain
line
Clean flow control, air check/draw tube, and
brine line. Clean any sediment from the brine
cabinet
Clean or replace injector. Replace throat if
removed
Remove valve. Check for obstruction
Replace magnet disk
Replace controller
Replace injector screen, nozzle, and throat
Maintain minimum pressure of 30 psi
Remove restriction
Remove restriction, replace if crimped
Verify correct water level relative to salt
setting. Check brine line and fittings for loose
connections
Check mode setting chart for proper brine
rinse time. Adjust time, if necessary
Install check valve on the inlet water line to the
appliance (Check local plumbing codes first)
Clean brine valve housing, replace piston
assembly
6/16/2014
Solution
35

Publicité

Table des Matières
loading

Produits Connexes pour Hague Quality Water MicroBoss II

Table des Matières