AIR SYSTEMS INTERNATIONAL ASI-1000 Manuel D'utilisation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Petro Vent™ Adapter Models ASI-212ADPT and ASI-29ADPT
Venturi
Attached to
Adapter
Underground Storage Tank
Venturi
Model
ASI-1000
ASI-1200
ASI-2900
ASI-4100
ASI-1000
ASI-1200
ASI-2900
ASI-4100
Venturi
Overall
Model
Length
ASI-1000
16.31"
ASI-1200
32.12"
ASI-2900
44.00"
ASI-4100
46.50"
This flange has been developed specifically to thread onto the 4" vent pipe
found on most storage tanks. (NOTE: Model ASI-12ADPT fits models ASI-1000
and ASI-1200 Venturi style air blowers. Model ASI-29ADPT fits model ASI-2900
Venturi style air blower.)
1. Using the supplied hardware, bolt Venturi air blower onto adapter.
2. Attach grounding wire between the base of the unit and the tank.
Do not restrict the internal diameter of the air blower base as severe
output flow loss will result.
3. Screw Petro Vent™ into 4" vent pipe on tank, and tightly secure the
air blower in place prior to turning on the air supply.
4. Attach compressed air source.
Note: Venturi style air blowers are NOT meant to be used with ducting on the inlet or
outlet as severe flow loss will occur.
American Standard Measurements
"Venturi Style Air Blowers"
Varioud Inlet Pressures
50 psig
Total Air Flow
935 cfm
1211 cfm
2770 cfm
3785 cfm
Air Consumed
38 cfm
38 cfm
76 cfm
117 cfm
Venturi Dimensions
Diameter
Diameter of
of Base
Top of Horn
7.38"
6.19"
7.38"
7.37"
11.16"
13.00"
14.31"
14.37"
3
70 psig
Total Air Flow
1274 cfm
1429 cfm
3340 cfm
4562 cfm
Air Consumed
53 cfm
53 cfm
99 cfm
152 cfm
NPT
Bolt
Size
Pattern
1/2"
6.75"
1/2"
6.75"
1"
10.28"
1"
13.18"
90 psig
Total Air Flow
1422 cfm
1580 cfm
3752 cfm
5041 cfm
Air Consumed
64 cfm
64 cfm
127 cfm
197 cfm
Base Slot
Net
Diameter
Weight
0.31"
5.3 lb.
0.31"
8.1 lb.
0.43"
22.1 lb.
0.56"
32.3 lb.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Asi-1200Asi-2900Asi-4100Asi-12adptAsi-29adpt

Table des Matières