3.6.12. Setting the production setpoint
Chlorinator
operating mode
%
Default display
Electrolysis
ORP
ORP Prod.
3.6.13. Setting the pH setpoint
Menu
pH Regulation
Setpoint
X.X
3.6.14. Setting the ORP setpoint
Menu
Electrolysis
From 200 to 900 mV, in increments of 10.
ORP Setpoint XXX
3.6.15. Boost mode
Boost mode :
- sets the production setpoint up to 125 %, for a fixed period.
- can be manually stopped at any time.
- can be used when chlorine is urgently needed.
I
Boost mode cannot replace a conventional shock treatment in cases of water not fit for bathing.
• If the Boost mode is restarted manually while it is already running, the Boost mode resets for the duration displayed.
• Boost mode cannot be switched on if an alarm has been triggered. After having resolved and dismissed this alarm,
wait a few moments in order to be able to activate the Boost mode.
• When the Boost mode ends or is manually stopped, production continues according to the initial setpoint.
• Boost mode continues after powering off the electronics unit.
Operation with a cover sensor :
• Boost mode cannot be switched on with the cover shut.
• If the cover is closed with Boost mode switched on, Boost mode automatically stops.
Possible
Menu
settings
• 12 h
Electrolysis
• 24 h
Boost
Menu
Specific instructions
Directly select a value using
the
confirmation required).
XXX %
Possible settings
From 6.8 to 7.6, in increments of 0.1.
Possible settings
Default
setting
Automatic as soon as the
24 h
duration setting is confirmed.
• From 1 to 100 %, in
buttons (no
increments of 1.
• 0 % or OFF (depending on
the operating mode of the
-
chlorinator).
Switching on
Possible settings
Default setting
7.2
Default setting
670 mV
Operation indicator
(specific display variants)
Bo 12 h
Bo 24 h
Boost 12 h
Boost 24 h
Default setting
100 %
Switching off
Press on
.
10