Display indicator
ALARM
Water supply
1.5 BAR
NORMAL 0
Air test
1.5 BAR

TROUBLESHOOTING

CAUTION!
Disconnect the mains plug before any fault rectification work. Faults in the electrical system
must be rectified by an expert electrician.
Malfunction
Pump motor does not
run
Fault message "Suction
Side" appears
ALARM
Water supply
1.5 BAR
Fault message "TOP
UP 1.5 BAR" appears.
If the faults cannot be rectified please contact our Customer Service Department.
ADVICE
22
Cause
Suction line not in the water,
no flow and no pressure.
Pump switches on after de-
lay.
Cause
No mains voltage
The suction line is not in the
water.
Suction line blockage
Pressure line blocked off
Pump drawing air into the
suction line
Pump drawing air, water
shortage on suction side.
Hose diameter too small
Water volume on the suction
side to little
Low air pressure in the stor-
age vessel
Actions
Message appears after 90 seconds. After rectifi-
cation of the fault the resetting of the fault mes-
sage is carried out by pushing the SET button.
Running text CHECK WATER INFEED
Measuring cycle:After a specific number of cy-
cles the pump switches on not at the switch-on
pressure, but rather waits approx. 25 seconds to
see if the pressure in the system drops to 1.5 bar.
If the pressure does not drop in this time, the air
filling is OK.
Rectification
Check fuses and power supply.
Submerge the end of the suction line into
the water by min. 30 cm.
Remove dirt from the suction area and filter.
Open the closing off devices in the pressure
line.
Check all the connections in the suction line
for leaks.
Replace seal ring.
Switch pump off and allow to cool.
Replace the pressure hose with one with a
larger diameter.
Throttle back the pump to adapt the flow
rate.
Top up the air in the storage vessel. (Set the
diaphragm pressure to 1.5 bar).
Running text TOP UP 1.5 BAR