TFA_No. 98.1105_Anleitung_
25.08.2011
Digital measuring cup with scale
10.1 Battery replacement (Fig. 2)
• Change the battery when the battery symbol appears on the lower left display edge.
• Open the battery compartment and insert a new battery CR 2450.
• Insert the new battery under the rubber holder.
• Make sure the polarity is correct (+ pole above).
• Close the battery compartment again.
11. Troubleshooting
Problems
Solutions
➜ Switch on the instrument
No display
➜ Ensure battery polarity is correct (insert under the rubber holder)
➜ Change battery
➜ Overload (max. 3 kg)
Display "Err"
➜ Surface is not flat
Display "unSt"
➜ Change battery
Incorrect display
If your device fails to work despite these measures contact the supplier from whom you pur-
chased it.
12. Waste disposal
This product has been manufactured using high-grade materials and components which can
be recycled and reused.
16
9:46 Uhr
Seite 9
Digital measuring cup with scale
Never dispose empty batteries and rechargeable batteries in household waste. As a
consumer, you are legally required to take them to your retail store or to appro-
priate collection sites depending to national or local regulations in order to pro-
tect the environment.
This instrument is labelled in accordance with the EU Waste Electrical and Electron-
ic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is obligated
to take end-of-life devices to a designated collection point for the disposal of elec-
trical and electronic equipment, in order to ensure environmentally-compatible
disposal.
13. Specifications
Capacity:
3000 g, 6 lb 6 oz
Resolution
Volume:
1/8 cups, 1/8 floz, 1 ml
Weight:
1 gram, 1/8 oz
Power consumption:
1 x CR 2450 button cell battery
Dimensions:
23,2 x 14,1 x 15,1 cm (W x H x D)
Weight:
523.0 g (incl. button cell battery)
TFA Dostmann GmbH & Co. KG, Zum Ottersberg 12, D-97877 Wertheim.
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct
at the time of going to print and may change without prior notice. www.tfa-dostmann.de
08/11
17