Sensor installation

2. Testing
• The system will automatically add
water to the high level sensing point.
• Test correct operation, lower the
water level below the low level
sensing point to see if the system
will automatically add water.
3. Important while testing
• Protective cover must be installed!
• The water outlet should not be aligned with the sensor!
• Anti-siphon prevention, if you stop the pump there is the risk of siphoning through the hose, make sure
the hose is above the maximum waterlevel at all times.
4. Alarm and resetting
• In the case of operational errors, such as water shortage in the water reservoir, or water supply exceeding
1 cm, the pump will stop after several attempts and alarm with a red flashing light.
• To stop the alarm, unplug power supply, re-plug and the device will resume normal operation.
• Reset the system if you change the configuration of your installation, unplug power and re-start the setup
process from step 1!
Maintenance
• Scale and salt settlement may influence proper functioning, regular cleaning is needed to ensure
proper operation!
• Disconnect power supply and pump from mains before any maintenance on the aquarium.
• Open and remove rotor and axle, to clean them.
• Clean sensors, impeller and shaft with 50% vinegar and 50% water solution. Let them soak for a
minimum of 15 minutes.
• Reassemble shaft and impeller verify that shaft caps are properly installed.
• Reassemble pump and place back in aquarium.
• The pump is a wearing part that depending on usage will need changing yearly, this is
considered normal maintenance and not covered under warranty.
• Replacement pumps, sensors and power supply are available at your dealer.
1. Setup
• Install the sensor at the desired water level.
• Plug in the power supply first, then plug in the pump.