A. Plug the wire into the correct Test Port, e.g. Ethernet to RJ45
B. Plug the opposite end into the Main Remote
C. Press Network Button
D. The LCD Display reports wire condition, Pass/Fail
E. To turn off, press O/ID Button
TONING:
A. With the unit turned OFF, hold down the LENGTH/TONE button until LCD
illuminates.
B. To select a tone cadence, press the LENGTH/TONE button repeatedly to step
through the four cadence options: HI, LO, Hi-Lo1, and Hi-Lo 2. Stop when you reach
the option you want. The option you select determines the cadence sent from the
main tester, through the cable, and picked up by the tone tracer probe*.
C. Press the appropriate cable type button (voice, video or data) to select a cable for
the tone signal.
* Note: Tone is detected by a tone tracer probe (optional).
LENGTH MEASUREMENT:
A. Make sure the CM450 is turned OFF.
B. Insert the cable plug into the corresponding receiver on the main tester (RJ-11/
RJ12) jack for voice cable, RJ-45 jack for data cables, F-Connector for video cables).
C. Press the LENGTH/TONE button to enter Length Mode.
D. Press the cable type button corresponding to the connector in use
FEATURES:
Testing: CM450 shows Opens, Shorts, Miswires, Split Pairs, PASS and FAIL results
quickly.
Toning: CM450`s built- in tone generator is a flexible and function- packed Tone
generator. Its configurable signal can be generated to find and fix the position on any
type of cable – either exposed or hidden, in ceilings or behind walls.
Length: CM450 determines the length (in feet or meters) of an entire cable and/ or
individual wire pairs within the cable.
Option: CM450 is supported by (1-19) wiremapping ID locators (Network/Coax) and
(1-8) testing/ID remotes (Network/Telephone).
3