Troubleshooting

Troubleshooting
Problem
Probable cause
The surge-protected
The circuit breaker
outlets stop
has tripped due to an
providing power to
overload.
devices. The circuit
breaker button is
projecting from the
side of your UPS.
The battery does not
The battery charge is
run as long as
depleted.
expected.
The battery is worn
out.
The UPS will not turn
The UPS is not
on.
plugged in.
The on/off switch is
designed to prevent
damage by rapidly
turning it off and on.
Mechanical problem
PowerPanel™
The USB or serial
Personal Edition
cable is not
software is inactive
connected.
(all icons are gray).
The USB or serial
cable is connected to
the wrong port.
Your UPS is not
providing battery
power.
The serial cable is not
the cable that was
included with your
UPS.

Specifications

Capacity
Solution
Input voltage on utility
Turn off your UPS
and unplug at least
Input frequency
one device. Wait 10
On-battery output voltage
seconds, reset the
circuit breaker by
Transfer time
depressing the
Max. load for UPS outlets
button, then turn on
(4 Outlets)
your UPS.
Max. load for full-time surge
Recharge the battery.
protection outlets (8 outlets)
On-battery output wave form
Replace the battery.
Operating temperature
Plug the UPS into an
Operating relative humidity
electrical outlet.
Size (L × W × H)
Turn off your UPS.
Wait 10 seconds,
then turn on your
Net weight
UPS.
Typical battery recharge time
Contact your
supplier.
Typical battery life
Connect the USB or
serial cable to your
UPS unit and an open
USB or serial port on
E
XPECTED RUNTIME IN MINUTES
the back of the
Because of the differences in computer components, the runtime will
computer. You must
vary.
use the cable that
came with your UPS.
Check the back of the
computer for an
additional USB or
serial port. Move the
cable to this port.
Shut down your
computer and turn
off your UPS. Wait 10
seconds, turn on
your UPS. This should
reset your UPS.
Use the serial cable

Legal notices

that came with your
UPS.
© 2005 Dynex. DYNEX and the DYNEX logo are trademarks of Best Buy
Enterprise Services, Inc. Other brands and product names are trademarks
or registered trademarks of their respective holders. Specifications and
features are subject to change without notice or obligation.
Support number: (800) 305-2204
URL: www.dynexproducts.com
800 VA /450 W
90 V to 140 V
57 Hz to 63 Hz
120 VAC ± 5 %
6 ms typical
800 VA /450 W
12 Amps
Simulated sine wave form
32°F to 95°F
0°C to 35°C
0 to 95 % non-condensing
11" × 6 5/8" × 3 1/2"
28 cm × 16.9 cm × 8.7 cm
14.3 lbs
6.49 kg
8 hours typical from total
discharge
3 to 6 years, depending on
number of discharge/recharge
cycles
Model
Runtime
iMac G4
70 minutes
Desktop PC with
45 minutes
LCD monitor
Desktop PC with
28 minutes
15" monitor
Desktop PC with
22 minutes
17" monitor
Desktop PC with
16 minutes
21" monitor
5