WINTERING PROCEDURE
The pool is equipped with systems allowing its use both
summer and in winter.
To prevent pipelines and components from freezing
up in cold weather, leave the system connected to
the electrical power supply so that the "antifreeze
protection" can come into operation if the water should
drop below 5 °C.
This function operates by activating the heater and
the whirlpool pumps in alternation until the water
temperature is raised to 7 °C.
If the minipool is not going to be used in winter, it should
be emptied completely. Proceed as follows:
- isolate the minipool from the power supply (1)
- Open the discharge outlet by removing the sealed
plug. Unscrew the ring to open the discharge valve
that permits the water to flow out of the mini-pool (2).
- using a liquids vacuum cleaner, remove water from
the bottom of the pool and from the jet outlets.
Remove and clean the filter, and store in a dry place
Cover the minipool with the canvas provided, so that it
will not collect dirt.
Before using the Teuco Minipool again after the winter
break, repeat the steps indicated for STARTING UP
FIRST TIME.
REMOVING SCUFFS, SCRATCHES AND CIGARETTE BURNS
Firstly, make certain that the scratch or burn
has affected only the surface of the acrylic
material.
This type of repair must be entrusted to a pro-
fessional with the necessary skills.
The repair will always be noticeable on the
surface of the mini-pool.
641 HR-HS
1
2
REPAIRS
ACRYLIC
FIBREGLASS
11