Problem
Kontrolle
Leuchtet die PWR LED ?
Kein Ton
Leuchtet die PROT LED ?
Keine Stromzufuhr
Verstärker schaltet
nicht ein
Keine Spannung am
Remote
Verstärker schaltet
Lautsprecherimpedanz
bei Lautstärke ab
prüfen
Ton Fehlt an einem
Cinch / Lautsprecherkabel
Kanal
prüfen

Trouble shooting / En cas... de non fonctionnement

This power amplifier has protection features to prevent any damages from misuse or faulty conditions. If the unit senses
excessive heat, short circuited speakers or overload, the protection indicators will light, and the system will be turned off. In
order to check the occurred problem, you should turn all levels down and all power off and carefully check the installation for
wiring mistakes or short. If the amplifier shuts down due to excessive heat, the protection indicators will not light: simply allow
time for the unit to cool. Before removing your amplifier, refer to the list below and follow the suggested procedures.
Always test the speakers and their wires first.
Problem
Amplifier is
not powered up
Protection LED illuminates
when amplifier is powered
up
Fuse blowing
Overheating
Sound too low / Distorted
sound
High hiss /
engine noise
in speakers
Cette amplificateur et équiper de protection pour éviter tous dégâts en cas de mauvaise manipulation .Si l'ampli détecte une
anomalie (court-circuits – surchauffe ) l'ampli se coupe automatiquement . Pour examiner le problèmes vérifier tous vos
branchements , le temps que l'ampli refroidisse . vérifier en premier les Haut parleurs puis tous les câbles d'alimentation . si le
problèmes persiste consulter un technicien.
Problèmes
Contrôle
Voyant PWR allumé?
Pas de son
Le Voyant PROTECTION
est allumé ?
Amplificateur ne
Pas d'alimentation
se met Pas en
Pas d'alimentation sur le
marche
REMOTE
Ampli se met en
Vérifier l'Impédance des
PROTECTION a
Haut-parleurs
haut Volume
Pas de son sur 1
Vérifier câble RCA et ou
canal
câble Haut-parleurs
Hilfe
Check points
Check that there is battery power on the +12V terminal.
Check that remote terminal has at least +12V DC remote connection.
Check a good ground connection. Check all fuses.
Check the protection LED is not lit.
Check shorts on speaker wires.
Remove speaker wires and reset the amplifier. If the protection LED still comes on,
then the amplifier is faulty.
Check that the minimum speaker impedance is correct.
Check short on power cable and vehicle chassis.
Check that the minimum speaker impedance is correct.
Check speaker shorts.
Check that there is a good airflow around the amplifier.
Check that the input level control is set to match the output level of the unit.
Check the head unit volume.
Check speaker shorts.
Check that crossover frequencies have been properly set.
Check a good ground and for speaker shorts.
Disconnect all RCA inputs from the amplifier. If hiss/noise disappears, check it with
a good RCA interconnect. Then check the component driving the amplifier.
Aide
Vérifier le fusible, Contrôler le Câble REMOTE, Contrôler
le+12Volt et la masse
Court circuit des Haut-parleurs, ampli surchauffe ou défectueux
Vérifier le + 12 volt, la masse, le fusible
Vérifier le REMOTE sur l'Autoradio
Vérifier si l'Impédance sur les connecteurs des haut-parleurs n'est
pas en dessous de 2
Vérifier si l'Impédance sur les connecteurs des haut-parleurs n'est
pas en dessous de 1
Câble ou prise (RCA) défectueux
Sicherung Prüfen
Remote Kabel prüfen
+12Volt prüfen
Masse prüfen
Kurzschluss am Lautsprecher
Gerät Überhitzt
Gerät defekt
Sicherung Prüfen
+12Volt prüfen
Masse prüfen
Remote am Radio prüfen
Prüfen Sie, ob der Widerstand am LS Terminal von 2 nicht
unterschritten wird
Kabel /Stecker beschädigt