eNet enjoliveur de volet roulant avec récepteur radio
Priority, sun protection
Priority, twilight
Slat change-over time
Fabric-stretching time
Running time
Minimum change-over-time
Invert movement direction
Operating hours up
Operating hours down
Information window
During channel selection in the Information window, the following settings can be made or va-
lues displayed.
Display value
32582613
J0082582613
0...4
Basic setting: 0
0...4
Basic setting: 0
0 ms ... 10 sec
300 ms ... 10 s
Basic setting: 0 ms / 300 ms
1 ... 600 sec
Basic setting: 120 s
300 ms ... 10 sec
Basic setting: 1 s
On, Off
Basic setting: Off
0...65535
Basic setting: Current value
0...65535
Basic setting: Current value
Explanations
6/7
Specifies the priority for recal-
ling and removing a scene of
type Sun protection for the
channel.
Specifies the priority for recal-
ling and removing a scene of
type Twilight for the channel.
Absolute time for changing-
over Venetian blind slats. The
fabric stretching time can also
be set here for the Awning
operating mode.
Absolute time which the
blind/shutter requires from the
top to the bottom end position.
The entry is essential if scene
or position movements are to
occur.
Minimum interruption time
when changing directions. In-
creasing the minimum
change-over time will cause
less wear on the motors.
Inverts the activation of the re-
lay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is re-
quired, for example, for
controlling skylights.
The time is counted during
which the load is physically
switched on (relay contact clo-
sed).
This parameter can be reset to
"0", for example after exchan-
ging the load.
The Reset button is used to
reset the meter to "0". The de-
vice must be programmed to
apply the change.
The time is counted during
which the load is physically
switched on (relay contact clo-
sed).
This parameter can be reset to
"0", for example after exchan-
ging the load.
The Reset button is used to
reset the meter to "0". The de-
vice must be programmed to
apply the change.
15.07.2016