Removing The Collected Water - Air Naturel Kompressor Notice D'utilisation

Masquer les pouces Voir aussi pour Kompressor:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
indicator light illuminates) and use
pads to settle the Auto Stop.
initialize Auto Start:
Press the timer button ⑥ two times (the "timer
on" indicator light illuminates) and use
pads to settle the Auto Start.
The selected time will register in 5 seconds
and the system will automatically revert back
to display the previous humidity setting.
When the Auto start & Auto stop times are set,
within the same program sequence, "timer on-
off" indicator lights illuminate identifying both
"on" and "off" times are now programmed.
CAUTioN: Turning the unit oN or oFF at any time
or adjusting the timer setting to 0.0 with
pads will cancel the Auto Start/Stop function.

reMovINg THe CoLLeCTeD WATer

Kompressor features three ways to remove
collected water:
1.
using the water tank
When the unit is off, if the bucket is full, the
Full indicator ⑩ will light.
Unplug the unit.
Pull out the water tank and throw the
water away.
Replace the water tank.
CAUTioN : When the water tank is full, the units
switches off.
Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight
so water does not spill. When you remove the
bucket, do not touch any parts inside of the
unit. Doing so may damage the product.
if the pump hose drops when you remove the
bucket (see Figure .1),you must reinstall the
pump hose properly to the unit before replace
the bucket into the unit (see Fig.2).
if the bucket is removed, the compressor and the
fan turn off, then the unit will beep 8 times and the
digital display shows "Eb".
2.
using the continuous draining
Continuous draining allows to drain the
collected water directly to a water outlet, by
gravity only and without using the water tank.
Remove the plastic cover from the back
14
When LED display window ⑨ displays the
code of P2, the Auto Start/Stop function will
also be cancelled.
Auto-restart
if the unit breaks off unexpectedly due to
the power cut, it will restart with the previous
function setting automatically when the
power resumes.
ATTENTioN : After Kompressor has stopped,
it can not be restart operation in the first 3
minutes. This is to protect the unit. operation
will automatically start after 3 minutes.
Auto defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
Retrait du réservoir
Vidange et replacement du
réservoir
1. Emptying the water tank
Pompe détachée
Pompe replacée
2. Repositioning the drain pump
drain outlet of the unit and set aside,
then.
insert the drain hose through the drain
outlet (Ø13.5 mm) of the unit and lead
the drain hose to the floor drain or a
suitable drainage facility (see Fig.3).
CAUTioN : Make sure the hose is secure so
there are no leaks and the end of the hose is
level or down to let the water flow smoothly.
Direct the hose toward the drain,making sure
that there are no kinks that will stop the water
flowing.
When the continuous draining feature is not
being used,remove the drain hose from the
outlet, and dry the water in the continuous
drain hose outlet.
3.
using the pump drain
Continuous draining allows to drain the
collected water directly to a water outlet
when it is impossible the make it with gravity.
The pump can lift the water up to 5 m high.
Remove the continuous drain hose from
the unit and install the plastic cover to
the continuous drain hose outlet of the
unit by clockwise rotation (see Fig.4).
insert the pump drain hose (Ø4,35 mm)
into the pump drain hose outlet for
depth of 15 mm at least (See Fig.4), then
lead the water hose to the floor drain
or a suitable drainage facility".
Press the pump pad ① of the unit to
activate the pump operation.
CAUTioN : The pump may cause big noise when
it starts to work for 3~5 minutes. it is a normal
phenomenon. The pump starts to work when
the bucket is full. Make sure the hose is secure so
there are no leaks.
Direct the hose toward the drain,making sure
that there are no kinks that will stop the water
flowing. Place the end of the hose into the
drain and make sure the end of the hose is
level or down to let the water flow smoothly.
Do never let it up.
The pump operation on light ① blinks when the
pump is operational failure. Please turn off the
unit and plug the power cord out. Check the
following things:
Remove the bucket from the unit, take
down the pump and clean the filter of the
pump (See Fig.5).
Continuous drainage
Placement of conti-
cap
nuous drainage hose
3. Installation of the continuous drain hose
Continuous drainage
Placing the pump drain
cap
hose
4. Installation of the drain pump hose
15