IDP58TY :
The connection box is located below the hob. To open the cover, use a medium screwdriver.
Place it in the slits and open the cover.
For the various kinds of connection, use the brass bridges which are in the connection box.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
*calculé avec le coefficient de simultanéité suivant Norme EN 60 335-2-6/1990
Monophase
230V~1P+N :
Put a bridge between terminal 1 and 2 and between 4 and 5.
Attach the earth to the terminal "earth".
Attach the neutral N to the terminal 4 or 5.
Attach the phase L to the terminal 1 or 2.
Biphase
400V~2P+N :
Put a bridge between terminal 4 and 5.
Attach the earth to the terminal "earth".
Attach the neutral N to the terminal 4 or 5.
Attach the phase L1 to the terminal 1 and phase L2 to the terminal 2.
Caution! Be careful to correctly engage and tighten the cables.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
61
Protection calibre
25 A *
16 A *