Back panel of the inverter:
Item
Description
K
Fan: Do not cover the vent holes !
L
Remote-Connector: Connect the wired remote control to this port
+ Positive battery terminal (red): Connect the positive pole of the battery to this
M
terminal
Only present at models PSI1000 & PSI1500:
Charging-Input for PV solar panels:
• Input voltage: 16-45V DC
• Input current/ power: max. 30A PWM (max. 500W)
• Output charging voltage: 7V DC – 14.4V DC
N
Observe polarity:
red-clamp:
black-clamp: terminal for negative cable of the input voltage
If polarity is accidentally reversed, the inverter will indicate an error.
NOTE: Only charge rechargeable lead-acid batteries. Please read the safety
instructions carefully before working with batteries.
O
Grounding terminal – Connect to ground
- Negative battery terminal (black): Connect the negative pole of the battery to this
P
terminal
8
terminal for positive cable of the input voltage