Pahlen Aqua-Mex Manuel D'utilisation page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Aqua-Mex
Standard Aqua-Mex:
1. Fit the two wall mounting brackets. Each bracket has 2 holes Ø6, c/c 91 mm. Note the c/c distance between the brackets for
each model, see the dimension diagram.
2. Place the heat exchanger in the brackets.
3. Connect the secondary circuit (the pool water).
4. Screw the brackets together.
After this, the pool's circulation system can be started up.
5. Connect the primary circuit. NB! The primary and secondary circuits' flow shall be in opposite
directions for maximum effect.
6. Check that the connections do not leak.
7. Bleed the primary circuit.
NB: The heat exchanger's existing nipples (A) on the primary circuit must not be removed.
Electrical installation (only for Aqua-Mex FE)
Electrical installation shall always be carried out
by an authorized electrician.
The Aqua-Mex FE shall be installed with a
protective ground and an earth fault relay.
However, the pump in the Aqua-Mex FE does
not require any external automatic circuit
breaker for the motor protection.
The electrical cable must be installed such that
it under no circumstances gets into contact with
the piping and/or the pump and motor housing.
Alternative flow direction
(only for Aqua-Mex FE)
The fully equipped Aqua-Mex FE can easily adjust
the heat exchanger's flowdirection to suit the
existing installation.
Aqua-Mex FE is supplied in version A.
If version B is required, follow steps 1-7 below:
1. Undo the screws.
2. Undo the screws
of the bracket.
3. Lift the bracket with
the control box on.
+45°
A
4. Rotate the bracket,
make sure the cables run free.
Aqua MEX ( 1N~ 230V )
Switch panel
J5:
FLOW
J3:
TEMP
Surface treatment
E
The tolerance class in accordance with this
Assembly drawing no.
part of ISO 2768-1
Aqua MEX fully equipped
flödesriktning
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
12
ENGLISH
A
L1
J2:
N
AC IN
J6:
L1
L1
PUMP
N
N
B
7. Fasten the
screws on the
cover. Done!
6. Screw the
bracket into
place.
5. Rotate it a total
of half a turn.
Designed by:
Drawn by: Date
Approved by:
OA
2010-05-19
Art.no.
11395X
Scale
Revised by: Date
OA
2010-08-31
Drawing number
Rev.no.
M11234 1
Prim
Do
L1
N
E
1

Publicité

Table des Matières
loading

Produits Connexes pour Pahlen Aqua-Mex

Ce manuel est également adapté pour:

Aqua-mex fe

Table des Matières