EVS17/07-DS/IU und EVS17/12-DS/IU
Refrigerator
Changeover switch to position K ==> compressor operation
The refrigerator is supplied via the permanent positive when the main switch is
turned on at the control panel.

Technical Data

Power supply
Output current
EVS 17/07-DS/IU: nically regulated according to the charging characteristic
Output current
Output voltage:
Charging process:
Autom. switching: ON when battery voltage reached 13,5 V
(Main charging
process)
Autom. switching: six hours constant at 14,4 V
(Timer)
Autom. switching: Holding charge constant at 13,8 V
(Holding charge)
Application:
Temperature:
Cooling:
Implementation:
Test labelling:
28
Trautmann GmbH & Co. KG
Lerchenfeldstr. 9
Operating instructions
Alternating voltage 230 V / 50 Hz, single phase
Range ca. 215 V - 245 V.
Charging current max. 7 A, arithmetic average, electro-
curve IUoU.
Charging current max. 12 A, arithmetic average, electro-
nically regulated according to the charging characteristic
curve IUoU.
12 V DC
automatic
OFF when battery voltage reached 14,4V
Parallel operation, buffer operation, general charging
operation
Ambient temperature of -25° C bis +25° C. During
operation, the housing may heat up to ca. 70° C.
by convection
According to Association of German Electrotechnical
Engineers regulations and the provisions of the Instrument
Safety Act.
87600 Kaufbeuren
Internet: http://www.calira.de
-Apparatebau
CALIRA
Tel.08341/9764-0 Fax 08341/67806
Email: info@calira.de