Replacing The Air Filter - Sygonix 2267647 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11. Replacing the air filter

You may need to replace your air filter every 6 to
8 months (sooner or later) depending on how often it is
used and how polluted the environment is.
Signs of an expired filter:
• Increased noise when the air purifier is on
• Decreased airflow
• Unusual odors
• Visibly clogged filter
2.
Remove the old air filter and properly dispose of it.
Un
4. Unwrap the new air filter and place it into the hous-
ing. Make sure the pull tabs are facing out.
Save the bag for storing / disposing filters.
1.
Switch the air purifier off and disconnect it from the
Un Un Switch SwSwitch
power supply, then remove the filter cover.
3. Clean any remaining dust and dirt from inside of the
housing using a vacuum.
5. Replace the filter cover.
6. Press and hold
"g) Reset the air filter indicator / lifetime" on page 25.
for 3 seconds to reset it. See
T he air purifier will
not power on if the
cover is not replaced
correctly.
27

Publicité

Table des Matières
loading

Table des Matières