Scope of supply

Scope of supply
Scope of supply
Scope of supply
Scope of supply
GB GB
GB GB
GB
Cillit Impulsor Optronic
metering unit with the option of connection to the
HydroModul system or a separate connecting
module or DR connecting module (not included in
delivery), consisting of:
1 1 1 1 1
Transformer plug, 230V~/12V~
2 2 2 2 2
Connection cable
3 3 3 3 3
Metering pipe
4 4 4 4 4
Injection point
5 5 5 5 5
Electronic controller with:
6 6 6 6 6
Display (7-segment, 2-digit) for operation/
metering
message, faults
A A A A A Terminal for power supply
B B B B B Connection socket for internal wiring
C C C C C Connection socket for water metre cable
D D D D D Connection socket, unassigned
E E E E E Connection terminals, unassigned
F F F F F Connection socket for suction lance
connector
T1
T1
T1 and T2
T2
T2 setting buttons for factor
T2
T1
T1
T2
7 7 7 7 7
Cap
8 8 8 8 8
Suction pipe (F3)
9 9 9 9 9
Suction lance (T20)
10
10
10
10
10 Connection cable gland
11
11
11
11
11 Childproof lock
12
12
12
12
12 Suction lance connector
13
13
13
13
13 Suction line
14
14
14
14 Return line
14
- - - - -
2 hose clamps (T20)

Intended use

Intended use
Intended use
Intended use
Intended use
Impulsor Optronic
metering units protect water pipes (pipe "sealing")
and attached fixtures and equipment, in particular
from lime and/or corrosion.
Function
Function
Function
Function
Function
The water metre in the mineral substance meter-
ing unit measures the water volume flowing
through and sends pulses to the electronic con-
troller. The controller controls the drive motor for
the piston metering pump, which proportionally
adds the active substance to the water flow using
the injection point (4 4 4 4 4 ). The metering frequency
appears on the display (6 6 6 6 6 ).
A built-in level monitor switches the unit off auto-
matically once the active metered substance has
been used up to prevent the metering pump from
running dry. An audio signal is also emitted.
1 2
1 2
1 2
1 2
1 2
®
module mineral substance
frequency,
reserve/empty
®
module mineral substance
The self-monitoring electronic controller reliably
prevents improper overdosage if a fault occurs
and switches off the unit. The fault appears on the
display (6 6 6 6 6 ) and is indicated by an audio signal.
Impulsor Optronic mineral substance metering
units are DVGW, ÖVGW and SVGW tested in the
original ex-works settings with Quantophos F
mineral substance combinations.
Replace container indicator/audio signal: If indi-
Replace container indicator/audio signal:
Replace container indicator/audio signal:
Replace container indicator/audio signal:
Replace container indicator/audio signal:
cator
appears and the audio signal is emitted,
the active substance container must be replaced
(indicator
flashes without
without
without
without audio signal = re-
without
serve).
If the message and audio signal do not switch off
once the container has been replaced, a fault has
occurred (see T T T T T roub
roub
roub
roubleshooting
leshooting
leshooting
leshooting).
roub
leshooting
Installation conditions
Installation conditions
Installation conditions
Installation conditions
Installation conditions
Observe all applicable installation regulations,
general guidelines and technical specifications.
In keeping with §16 of the German regulations on
the preparation of drinking water, notify residents
that the dosing unit is installed and explain how it
works and what active substance is used.
Note:
Note:
According to A
According to A
VB
VB W W W W W asser
VB
Note: According to A
Note:
Note:
According to AVB
According to A
VB
the water supply company or a party registered
the water supply company or a party registered
the water supply company or a party registered
the water supply company or a party registered
the water supply company or a party registered
in the w
in the w
ater supply compan
ater supply company' y' y' y' y's inde
ater supply compan
in the water supply compan
in the w
in the w
ater supply compan
may install the unit or modify its basic design.
may install the unit or modify its basic design.
may install the unit or modify its basic design.
may install the unit or modify its basic design.
may install the unit or modify its basic design.
If hot-water units are installed downstream, a non-
return valve should be installed. Metering units
have an integrated non-return valve and must
not be installed between the hot water heaters
and excess pressure valve.
A protective filter must be installed upstream from
the mineral substance metering unit to protect
the unit from foreign particles.
The installation site must be protected against
frost and must guarantee the protection of the
unit from all types of chemicals, paint, heating oil,
lees, solvent vapours, heat sources above 40°C
and direct sunlight.
The electrical outlet must be no more than 1.2m
from the mineral substance metering unit.
asser
asser
V §12.22, only
V §12.22, only
asser V §12.22, only
asser
V §12.22, only
V §12.22, only
s inde
s inde
x of fitters
x of fitters
s index of fitters
s inde
x of fitters
x of fitters