Cleaning, Care & Maintenance - Buffalo HE154 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Cleaning, Care & Maintenance
Always disconnect the appliance from the power supply and let it cool down
before cleaning and maintenance.
Use soapy water and a damp cloth to clean the exterior of the appliance.
Dry thoroughly after cleaning.
NEVER immerse the appliance in water.
De-scaling
For the best water quality, Buffalo recommend that a water filter is installed to the mains water supply,
particularly in hard water areas. Doing so will reduce the build up of limescale and contaminants in the
water tank thus maintaining energy efficiency and prolonging the life of the appliance.
To de-scale the appliance:
Fill the inner pot with water and lemon juice (or a suitable de-scaler), and boil.
Discard the solution. Note: Always run water through the appliance after de-scaling to rinse
the inner pot and tubes.
Note: Use a suitable de-scaler and always follow the instructions on the packaging.
Buffalo recommend that this appliance is de-scaled every 3 months or more frequently in
hard water areas.
IMPORTANT: Failure to de-scale or maintain will invalidate your guarantee.
Troubleshooting
Fault
The unit is not
The unit is not switched on
working
Plug or lead is damaged
Fuse in the plug has blown
Power supply
Steam leaks from
Seal worn
the silicon seal
No water is
Seal deformed or lost pliancy
pumped out
When the water just gets
boiled, there is too much
steam accumulated inside the
pot
Unit stops working
No water inside so boil dry
suddenly, "Empty"
protection is activated
indicator on
HE154_HF155_ML_A5_v1_20211014.indb 5
HE154_HF155_ML_A5_v1_20211014.indb 5
Probable Cause
Check the unit is plugged in correctly and switched
on
Call Buffalo agent or qualified technician
Replace the plug fuse
Check power supply
Call Buffalo agent or qualified technician
Call Buffalo agent or qualified technician to have
the silicon seal replaced
Once temperature has been reached, please allow
several seconds for the pressures to equalise prior
to activating the pump
Allow to cool thoroughly before re-filling
UK
Solution
5
2021/10/14 15:04
2021/10/14 15:04

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hf155

Table des Matières