UK │ 1. General notes
1. General notes
Before mounting read these
instructions carefully and follow
the information they contain.
Keep the instructions safe for
use later on.
2. Intended use
MF-VK90-7 air distributor for connecting of up
to 7 MF-F flexible ducts from the MAICO
flexible duct system. Serves to distribute air
in the supply air or exhaust air ducts in the
interiors of apartments or houses.

3. Safety instructions

WARNING
Risks for people (including
children) with reduced
physical, sensory or mental
capabilities or a lack of
knowledge.
 Air distributor may only be
installed, commissioned,
cleaned and maintained
by people who can safely
recognise and avoid the
risks associated with this
work.
Acknowledgements:
© MAICO Elektroapparate-Fabrik GmbH. Translation
from German of the original mounting and operating
instructions. We cannot be held responsible for
mistakes or printing errors and retain the right to
make technical modifications without giving prior
notice.
4
4. Figures
Fig. A: Fixing points - threaded rods
Fig. B: Installation example - air distributor
on sound absorber boxes and ventilation unit
Fig. C: Unit overview
1 EPP housing, sound-insulated
2 Connection socket - folded spiral-seams duct
Ø 125 for plug connector [7]
Ø 160 directly on EPP housing sockets
3 Flexible duct connection Ø 90
4 Cover - inspection opening (2 pieces)
5 Sealing plugs (5 pieces)
6 MF-F (Ø 90) flexible duct, optional
7 SVR 125 plug connector, optional
T Rating plate
Fig. D: Space-saving installation
Fig. E: Installation example: flexible duct
positions
Fig. F: Connection - folded spiral-seams duct
Ø 125/160
Installation with the "click": MF-F
flexible ducts are simply inserted into
the housing. Seal integrity through
the sealing lips integrated into the
housing.
5. Scope of delivery
Air distributor, 2 covers for inspection ope-
nings, 5 sealing plugs and these installation
instructions.
6. Qualification of installation staff
Installation should only be performed by
ventilation specialists. You are considered a
ventilation specialist if your specialist training
and experience enables you to correctly and
safely undertake installation in accordance
with these instructions. In addition, you must
be able to recognise, assess and avoid risks
due to incorrect installation.

7. Technical data

Dimensions (LxWxH): 485 x 300 x 218 mm
Weight:
0.8 kg