5.
MEASUREMENTS
MODEL
ECOCOMFORT 160
ECOCOMFORT SAT 160
ECOCOMFORT 100
ECOCOMFORT SAT 100
FAN UNIT WITH HEAT RECOVERY
E
A
* For wall thickness of less than 280mm, cut the pipe according to necessity
and use a standard outdoor grill (not supplied).
6.
INSTALLATION - WALL PREPARATION
Make a hole, through the whole thickness of the wall, of a minimum diameter of ØD, with an inclination of 1°
towards the exterior. The hole should be located at a minimum height of 2.3m from the ground and 100 mm from
the wall side (Figure 1).
ØD
AP19980
162 mm
AP19979
162 mm
AP19984
110 mm
AP19985
110 mm
Using two monostanza ventilation systems with Ecocomfort heat recovery series in the same environment, when
mounted on the same wall (figure 2a), the installation must be carried out in such a way that the centers of the
drill holes are at a minimum distance of 1.2 meters.
A
B
C
D
160
530
160
530
180
47
107
570
107
570
max C*
min 100mm
E
F
G
20
190
140
GRID INSIDE/
OUTSIDE
D
ROOM
E N G L I S H
ECOCOMFORT Series
H
I
L
85
140
85
CONTROL
UNIT
G
POWER SUPPLY
I
EXTERNAL
Figure 1
13