Electrical Connections; Maintenance Instructions - QEP 60095 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

This Owner's manual will
operate the QEP 60095 water pump. This pump is carefully inspected and tested to
ensure both safety and operational performance. However, failure to follow the
instructions and warnings in this Owner's manual may result in damage to the
pump and/or serious injury. Be sure to read and save this Owner's manual for future
reference. Note: Pump is fully submersible.
OPERATION:
1.
The
QEP 60095 water pump must be operated in clean water and can be placed in
any position so long as the intake is below the water level.
2. The weight of the pump must be adequately supported and resting inside the water
tray.
3. The discharge is designed for use with 1/2" ID flexible tubing. An adapter that fits
inside of the discharge is included to allow the use of 3/8" ID flexible tubing.
4. The flow rate on the
adjuster located on the front of the pump. Rotate the adjuster counterclockwise to
increase flow and clockwise to decrease flow.
5. If the pump is going to be idle for a period of time, follow the cleaning instructions.
Do not allow the pump to freeze, which may cause cracking or distortion and
destroy the pump.
6. A clogged or dirty intake screen or filter will greatly reduce performance. If the
pump is used on a dirty surface, raise it slightly to reduce the amount of debris
contacting the intake.
7. Do not let the pump run when not submerged in water. Doing so may damage the
pump. Always submerge the pump before plugging it into the electrical outlet.
Occasionally, due to air in the pump and tube, water will not pump. To initiate
water flow, pull the pump out of the water and insert the plug into the electrical
outlet several times.

ELECTRICAL CONNECTIONS

1.
This pump is supplied with a grounding conductor and a grounding type
attachment plug. To reduce risk of electric shock, connect only to a properly
grounded outlet.
2. Do not remove the grounding pin from the plug.
3. Do not connect to any voltage other than that shown on the pump.
4. Do not pump flammable liquids.
5. Do not use with water above 86°F (30°C).

MAINTENANCE INSTRUCTIONS:

MONTHLY MAINTENANCE WILL INCREASE THE LIFE OF THE PUMP. BEFORE
SERVICING THE PUMP, PLEASE FOLLOW THESE BASIC RULES:
1.
Always disconnect from electrical outlet before handling the pump.
2. Do not let the pump run dry.
3. Do not lift the pump by the power cord.
4. Operate in clean water only.
5. Operate pump completely submerged for proper cooling.
WARRANTY:
The QEP 60095 water pump is
against defects in workmanship or materials. Proof of purchase must accompany the
pump when submitting it for repair. The pump must be sent postage paid. This
warranty is only valid for the replacement or repair of defective parts and is considered
void if the pump is improperly used or handled, or if damages are caused by the
negligence on the part of the buyer. Any defective pump returned under warranty will be
fully inspected by Q.E.P. to determine cause of the failure before warranty is approved.
provide you with information required to safely own and
QEP 60095 water pump can be adjusted by
(WARNING!)
warranted for 90 days from the date of purchase
rotating the flow

Publicité

Table des Matières
loading

Table des Matières