A. High sensitivity : when the motor is rotation, will meet some minor resistance, then control board will
send a signal to let motor stop rotating.
B. Low sensitivity : when the motor is rotation, will meet greater resistance, then control board will
send a signal to let motor stop rotating.
C. As picture show : when pointer rotate to black part, the control panel will quit this syste
7.3 Programming setting: 8 settings on the control board.
1: Optional limit modes.
OFF : NC mode (Factory setting)
ON : NO mode.
Limit-switch direction's setting (J1):
Normal: Short circuit cap simultaneously No.1 and No.2 of J1 (Factory setting).
If motor system installed at left of gate. Please adjust the J1. Short the cap simultaneously No.2 and
No.3.
2: Infrared mode.
OFF: NC mode (Factory setting).
ON: NO mode.
If the gate meets obstacles during closing, it will auto-stop and auto open. After the gate complete
open it will auto-close again if the obstacle disappears within 2s, if not, it will not auto-close until to
the obstacle disappears.
3 & 4: Auto-close setting time.
The auto-close function activated after gate complete opens to its place and stop by limit switch:
• No° 3 &4, OFF-OFF: Auto close function disabled (Factory setting)
• No° 3 &4, ON-OFF: 10S
• No° 3 &4, ON-ON: 30S
• No° 3 &4, OFF-ON: 60S
7.1 / 7.2 Gate open and close - blocked detection
7.2
Close sentivity
adjusting
Open sentivity
adjusting
7.1
EN
7.3
Programming
setting