SDO-10 Assembly and start-up
Thank you for purchasing this safety door opener SDO-10 module. This
is suitable for connection to the VISTADOOR and VISTUS door intercom
systems and facilitates the control of the door opener. The SDO-10 can
also open a connected door opener within seconds after the bell is
rung. This is helpful in medical practices, for example.
Legend
1. SDO-10
2. Connector terminal to the door intercom system
3. Connector terminal to the door opener
4. Nose for top-hat rail
5. Fixing clip (spring)
6. Groove for top-hat rail
7. Switch for the ID code
8. Switch for opening
10. Power LED
ATTENTION
Do not expose this device to high temperatures, high humidity or
extreme dust.
Do not expose this device to hard blows.
Do not install this device outside.
This device must be installed by a professional.

Technical Specifications

Input: 15 Volt DC, closed-circuit current approx. 6mA (approx. 0.9 Watt)
Output: 12 Volt DC, max. 1 A
Measurements (width x height x thickness): 78mm x 92mm x 57mm
(4 TE)
Assembly
This device can be snapped-on to norm profile rails DIN EN 50022 - 35
x 15 and DIN EN 50022 - 35 x 7.5. In order to snap the device in, hook
it in and press the top-hat rail with the nose (4) until the spring (5)
snaps into place. If it is difficult to snap it in, release the spring (5) a
little with a screwdriver in the direction of the arrow.
In order to release the SDO-10 from the profile rails, press the spring
with a screwdriver in the direction of the arrow and remove the SDO-10.
Connection
Connect the 4 poles of the connector terminal (2) to the four signal
lines of the door intercom system with corresponding polarity. 15V with
+15V, GND with GND, Audio with Audio and Video with Video (if the
door intercom system does not support video, the video terminal on the
SDO-10 should be left unconnected).
Connect the door opener with both terminals of the connection terminal
(3). As your door opener must be correctly polarized, the two terminals
are labeled with "+" and "-".
Set ID code
Please note: Current to the system must be shut down in order to
change the ID code.
The SDO-10 must have the same ID code as the corresponding external
station. The external stations and the SDO-10 are set to ID 1 at the
factory so that there is no adjustment necessary here. If you have
assembled multiple external stations, the ID code of the SDO-10 must
correspond to the ID code of the external station where the door opener
is located.
The ID code is set as follows for both switches (7):
Switch 1 ON and Switch 2 ON
Switch 1 ON and Switch 2 OFF
Switch 1 OFF and Switch 2 ON
Switch 1 OFF and Switch 2 OFF
8
= ID code 1
= ID code 2
= ID code 3
= ID code 4