Installing And Connecting The Pump - Dometic PP 127 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20

Installing and connecting the pump

6
Installing and connecting the pump
6.1
Installing the pump
A
NOTICE!
Choose an installation location where the pump will be protected from
water penetration and moisture.
I
NOTE
When selecting the installation location, note the following:
• The pump can be installed either horizontally or vertically (with the
pump motor at the top).
• A coarse filter must be used in the pump inlet. If you install the pump
in a place which is not readily accessible, instead of using the coarse
filter provided (which is inserted directly onto the pump) you can use
a different coarse filter in a more accessible place.
➤ Remove the plugs (fig. 1 7, page 3) from the connections.
➤ If necessary, open the slide valves (fig. 2 1, page 3) on the inlet and outlet.
➤ Insert the coarse filter (fig. 2 3, page 3) in the inlet and a suitable adapter
(fig. 2 2, page 3) in the outlet.
➤ Lock the adapter and coarse filter with the slide valve (fig. 2 1, page 3).
➤ Slide the four fastening feet (fig. 1 6, page 3) into the holders.
➤ Install the pump in a vibration-free location using suitable fastening materials.
6.2
Connecting the pump to the water system
➤ Connect the pump to the water system using suitable pressure-proof connection
1
hoses (
/
").
2
➤ Fix the hoses to the connections using hose clamps.
➤ In the water system, attach pipes of at least
8
3
/
" to the fittings.
8
PowerPump
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pp 1210Pp 1217

Table des Matières