Favero Electronics TA1w Mode D'emploi Et D'installation page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.3.
Connecting circuit of the solenoid valve 12Vdc
The solenoid valve should be connected to the terminals of the electronic board as indicated in Fig 5 or in Fig 6. Use a
solenoid valve 12Vdc with a maximum absorption of 10W. Use cables with a cross section of 1.5 – 2.5 mm
2
section of 1.5 mm
will suffice if the length of the solenoid valve's connecting cables is less than 20 m.
3.4.
Fastening the cables
WARNING. Once all the electrical connections have been made, make sure they are securely fastened. Then proceed to lock
the cables in place by clamping them to the appropriate cable clamp, shown in Fig 4.
Fasten the protection case to the TA1w version 100-240V as shown in Fig 3. Then make sure that no live circuits can
be touched by operators when emptying the coin drawer and that no risks can occur during programming.
1) Fastening screws of the protection case.
Fig 3: Protection case of the connections, present only
on the TA1w version 100-240V
5197000015 TA1w manuale di uso e inst
1) Entrance for cables (grommets).
2) Holes for fastening to wall.
3) Electronic board.
4) Power supply (Only for TA1w version 100-240Vac).
5) Cable clamp.
Fig 4: Mounting the TA1w
Pag. 6 / 32
ENGLISH
2
. A cross
www.aus.at

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5197000015

Table des Matières