arietta ASG430SSA Instructions D'installation page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wall Installation
Install framing for hood support
1. Mark the screw hole locations indicated in the "Outside rear
exhaust" figure.
2. If drywall is present, cut away enough drywall to expose 2
vertical studs at the indicated holes location. Install two
horizontal supports between two wall studs at the bottom and
upper mounting holes installation location.
3. The horizontal support must be flush with the room side of the
studs. Use cleats behind both sides of the support to secure
wall studs.
4. Reinstall drywall and refinish.
IMPORTANT: Framing must be capable of
Centerline of
Installation
Space
5. Cut holes at marked locations for duct and electrical wiring.
Mounting the hood
1. Drive a mounting screw (from the hardware package) partway
into each center of the narrow neck of the keyhole slots
marked on the wall's support frame.
NOTE:
You should consider the wall's construction material in
order to choose the right wall anchor and screw. For plywood
walls you should use the 10x60 mm wall anchors and the 5.4x75
mm screws. For concrete walls you should use the 8x40 mm wall
anchors and the 5x45 mm screws
2. Install the 2 pieces of the selected screws on the mountings
screws location (see the image). Leave a
between the wall and the back of the screw head to slide
range hood into place.
"
1
4
(6.4 mm)
3. Fix the wiring conduit of the hood.
supporting 100 lbs.
View from rear
Cleats
Mounting
Support
" (6.4 mm) gap
1
4
4. Slide the hood back against the wall. Tighten the mounting
screws. Be sure the screw heads are in the narrow
neck of the keyhole slot.
B
C
A. Mounting Screws
B. Upper security screws (Wall Installation)
C. Lower security screws (Wall Installation)
5. Drive 2 pieces of the selected screws in the upper security
screws location (see the image above).
6. Drive 2 pieces of the selected screws and washers in the
lower security screws location (see the image above).
7. Connect Ductwork to hood.
Recirculating Kit EXXRCK10
If it is not possible to vent cooking fumes and vapors to the
outside, the range hood can be used in the non-vented
(recirculating) version, using a charcoal filter and a recirculating
grid placed on the soffit.
Recirculating through
the cabinet top wall
A
G
B
F
D
H
A. Ceiling
B. Recirculating grid
C. Soffit
D. 6" round vent system
7
A
B
D
D. Washers
E
E. Range hood
F. Cabinet
G.Wall
H. 3
"x10" rect. to 6" round converter
1
4