Troubleshooting - Hilti DX 460 Mode D'emploi

Masquer les pouces Voir aussi pour DX 460:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43

9. Troubleshooting

Fault
Piston is stuck in the base
material
Cartridge not transported
Cartridge strip cannot be
removed
Cartridge cannot be fired
Cartridge strip melts
Printed: 08.07.2013 | Doc-Nr: PUB / 5069834 / 000 / 02
Cause
■ Fastener too short
■ Fastener without washer
■ Driving power too high
■ Damaged cartridge strip
■ Carbon build up
■ Tool damaged
■ Tool overheated because of high
setting rate
■ Tool damaged
WARNING
Never attempt to pry a cartridge
from the magazine strip or tool.
■ Bad cartridge
■ Carbon build-up
WARNING
Never attempt to pry a cartridge
from the magazine strip or the tool.
■ Tool is compressed too long
while fastening.
■ Fastening frequency is too high
Possible remedies
■ Remove the cartridge strip and
push the piston all the way back
(see 8.3-8.14)
■ Use longer fastener
■ Use fastener with washer for
wood applications
■ Reduce power setting
• Power regulation
• Lower cartridge power level
■ Change cartridge strip
■ Clean the cartridge strip guide-
way (see 8.11)
If the problem persists:
■ Contact Hilti Repair Centre
■ Let the tool cool down and then
carefully try to remove the
cartridge strip
If not possible:
■ Contact Hilti Repair Centre
■ Manually advance the cartridge
strip one cartridge
If the problem occurs more
often:
Clean the tool (see 8.3–8.14)
If the problem persists:
■ Contact Hilti Repair Centre
■ Compress the tool less long
while fastening.
■ Remove the cartridge strip
■ Disassemble the tool (see 8.3)
for fast cooling and to avoid
possible damage
If the tool cannot be disassembled:
■ Contact Hilti Repair Centre
en
29

Publicité

Table des Matières
loading

Table des Matières