LP GAS CYLINDER (TANK) SPECIFICATIONS:
LP gas cylinder (not supplied with this grill)
The LP (Liquid Propane) gas cylinder specifically designed to be used with this grill must be 12" (30 .5 cm)
diameter x 18" (45 .7 cm) tall and have a 20 lb . (9 .1 kg) capacity incorporating a Type 1 cylinder valve and
an over-filling protection device (OPD) .
This grill is designed to fit Worthington, Manchester or SMPC brand 20 lb . (9 .1 kg) cylinders . Other brand
DOT cylinders may fit this grill if cylinder has similar dimensions of top and bottom rings .
The installation of this appliance must be in accordance with:
All applicable local codes, or in the absence of local codes, either:
•
National Fuel Gas Code ANSI Z223 .1 NFPA 54
•
Natural Gas and Propane Installation Code: CAN/CGA B149 .1
•
Natural Gas Installation Code: CAN/CGA B149 .1 (Canada)
•
Propane Installation Code: CAN/CGA B149 .2 (Canada)
To check your local codes, see your local LP gas dealer or natural gas company .
When purchasing or exchanging a cylinder for your gas grill, it must be constructed and marked in
accordance with specifications for LP gas cylinders of the U .S . Department of Transportation (DOT) or
the National Standard of Canada, CAN/CSA-B339 Cylinders, Spheres and Tubes for Transportation of
Dangerous Goods; and Commission, as applicable; and provided with a listed over-filling prevention device
(OPD), and provided with a cylinder connection device compatible with connection for outdoor cooking
appliances .
The cylinder must also be equipped with:
•
A shut-off valve terminating in a Type 1 gas cylinder valve outlet .
•
A Type 1 valve that prevents gas flow until a positive seal is obtained .
•
An arrangement for vapor withdrawal .
•
A collar to protect cylinder shut-off valve .
•
A safety relief device having direct communication with vapor space of the cylinder .
•
A listed over-filling prevention device (OPD) .
FILLING THE LP GAS CYLINDER (TANK):
•
Allow only qualified licensed LP gas dealers to properly fill or repair your LP gas cylinder.
•
New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.
•
DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a
dangerous condition. Over-filled tanks can build-up pressure and cause the relief valve to expel
propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or
flame an explosion causing severe burns, bodily harm, or death could occur.
•
Always use a protective cylinder cap when grill is not connected to cylinder.
•
If you exchange a cylinder with a qualified exchange program, the new cylinder must have
a Type 1 valve and an over-filling prevention device (OPD).
•
Inspect the propane tank valve rubber seal for cracks, wear or deterioration prior to use. A
damaged rubber seal can cause a gas leak, possibly resulting in an explosion, fire or severe
bodily harm.
5