bringing this device into service. If the device was damaged in transit,
don't install or use it and contact your dealer.

2. Safety Instructions

Do not use any liquids when cleaning the traps' internal
parts. Only use the brush that came with the mosquito trap.
Do not stare at the light from the UV-lamp. Permanent eye
damage may occur.
Keep this device away from rain and moisture.

3. Replacing the UV-lamp

Refer to the pictures of this manual.
• Switch off the lamp and disconnect from the mains.
• Remove the collecting container by twisting the container counter
clockwise and pull. Now, twist the lamp holder section and pull from
the fan section.
• Gently unstick the electrical wire. Remove the 4 screws to uncover
the PCB. Now, slide the PCB out of the notches.
• Unsolder the connections of the lamp to the PCB. Remove the lamp
and replace with a new one. Solder the connections to the PCB.
Slide the PCB back into the notches.
• Screw the PCB holder back into the lamp holder section with the 4
screws.
• Reassemble by repositioning the lamp holder section back onto the
fan section and by twisting the container back onto the assembly.