Hot water storage tanks
Real volume according to EN 12897
Fire protection class of insulation according to DIN 4102-1
Total height including insulation
Diameter without insulation
Diameter with insulation
Tilt height
Weight
Energy efficiency class according to EU regulation
no. 812/2013
Heat retaining loss according to EN 12897
Output capacity 45 °C
(storage tanks 65 °C, cold water 10 °C, no reheating)
Performance factor NL following DIN 4708
Storage tank pmax / tmax
Smooth-pipe heat exchanger surface /volume
Smooth-pipe heat exchanger pmax / tmax
Cold water connection (R 1")
Return smooth-pipe heat exchanger (Rp 1")
Sensor sleeve (Ø 6 mm)
Flow smooth-pipe heat exchanger (Rp 1")
Circulation connection (R ¾")
Sensor sleeve (Ø 6 mm)
Hot water connection (R 1")
Anode connection (Rp 1¼")
Hot water connection (R 1")
Thermometer (Ø 9 mm)
Heating element connection (Rp 1½" )
Service hatch, also used as heating element connection!
(bolt circle Ø 150, 8 x M12)
H
400, 500 l
400,500l
G
F
E
D
C
B
A
Enamelled domestic water storage tanks
150
[l]
154
[-]
B2
[mm]
1020
[mm]
500
[mm]
610
[mm]
1170
[kg]
70
[-]
A+
[W]
28
[l]
236
[-]
3
[bar] / [°C]
10 / 95
[m²] / [l]
1.15 / 7.5
[bar] / [°C]
10 / 130
A [mm]
132
B [mm]
207
C [mm]
262
D [mm]
607
E [mm]
705
F [mm]
807
G [mm]
-
H [mm]
963
I [mm]
1019
J [mm]
762
K [mm]
-
L [mm]
292
150, 200, 300 l
150,200,300l
I
J
K
L
Anode 400,500l
anode 400, 500 l
Hot water storage tanks
200
300
201
294
B2
B2
1265
1750
500
500
610
610
1375
1830
80
98
A+
A+
31
36
315
471
5
10
10 / 95
10 / 95
1.15 / 7.5
1.15 / 7.5
10 / 130
10 / 130
132
132
227
227
405
400
627
627
725
987
927
1347
-
-
1209
1694
1264
1749
910
1405
689
1145
292
304
I
150,200,300l
150, 200, 300 l
400, 500 l
H
400,500l
H
150, 200, 300 l
150,200,300l
27
7.1
150 – 500
400
500
411
507
B2
B2
1725
1770
600
650
710
760
1865
1925
119
150
A+
A+
40
43
628
785
13
19
10 / 95
10 / 95
1.88 / 12.3
1.88 / 12.3
10 / 130
10 / 130
120
127
218
217
474
481
748
747
930
967
1265
1283
1575
1597
1695
1731
-
-
1370
1411
895
910
300
325
GB