OPERATING MODES

Normal Operation (Utility Power) Mode
When connected to a live power source, the F1000-UPS provides power and is ready to provide protection from under- and over-
voltages.
Rotate the navigation dial to scroll through the screens.
Automatic Voltage Regulation (AVR) Mode
Sensitive AVR: when receiving input voltages of 99 VAC – 135 VAC, the F1000-UPS supplies a regulated voltage of
120 VAC ± 5%.
Standard AVR: when receiving input voltages of 94 VAC – 142 VAC, the F1000-UPS supplies a regulated voltage of
120 VAC ± 10%.
OFF: AVR is disabled. No voltage correction.
UPS Mode
In the event of a loss of power to the unit, over-voltage, or under-voltage, the F1000-UPS will function as a battery back-up. An
audible alarm will sound and the display will indicate the fault as well as the number of minutes of battery life remaining.
Setup Mode
The setup menu allows the user to adjust several of the operating parameters of the unit.
Please refer to diagrams on page 53 for a detailed map of the menu structure.
Setup Menu Navigation
Clockwise (CW) rotation of the navigation dial advances the menu to the next item. If the menu is at the last item, SYSTEM INFO,
return to Normal Operation Mode.
Counter clockwise (CCW) rotation of the navigation dial sends the menu to the previous item. If the menu is at the first item,
DISPLAY BRIGHTNESS, return to Normal Operation Mode.
Pressing the navigation dial selects the current menu item.
If there is no activity of the navigation dial for 60 seconds, the menu will automatically return to Normal Operation Mode.
Parameter Selection and Adjustment
CW rotation of the navigation dial INCREASES the selected parameter, or advances to the NEXT available value.
CCW rotation of the navigation dial DECREASES the selected parameter, or goes back to the PREVIOUS value.
Pressing the navigation dial selects the current parameter value.
If there is no activity of the navigation dial for 60 seconds, return to Normal Operation Mode.
If the BACK parameter is selected, return to the menu item selection.
Display Brightness
Display Brightness adjusts the brightness of the display backlight.
Display Scroll Mode
If enabled, the display will automatically advance to the next screen every 5 or 10 seconds.
Display Sleep Mode
With Display Sleep Mode enabled, the Display will go to the lowest brightness setting (25%) after the designated time of inactivity
of the Navigation Dial {30 SEC, 60 SEC }.