FEATURES
Rotation axle on self-adjusting bearings.
Easy tool change.
The handpiece is available in the following models:
handpiece slip connection with collet ø 2,35 mm
handpiece flexible connection with collet ø 2,35 mm
handpiece duplex connection with collet ø 2,35 mm
handpiece USA connection with collet ø 2,35 mm
handpiece slip connection with collet ø 3 mm
OPERATING INSTRUCTIONS
Check packing to see that all parts of the laboratory handpiece are received, as follows:
Handpiece
Annexed documentation
Fit the handpiece by pushing it into the flexible shaft connection by taking care to position the
reference notch with the connection system.
To insert the tool shank in the handpiece collet move the lever (2) to position B (collet open). To lock the
tool move the lever (2) to position A (collet close).
Run the handpiece without load for a few seconds to make sure it rotates properly.
(cod. 010.000)
(cod. 011.000)
(cod. 011.020)
(cod. 012.000)
(cod. 014.000)
17
INSTALLATION OF HANDPIECE
18
CHANGING TOOL
19
HANDPIECE MUST ROTATE ONLY WITH
THE FITTED TOOL.
NEVER BRAKE ROTATION BY USING THE LEVER.
20
If you have difficulty in
withdrawing the tool shank,
do not force it but on the contrary
push it inward to facilitate
opening of the collet.