ENGLISH
1)
INSTALLATION INSTRUCTIONS
2)
Automatic surface-mounted soap dispenser
3)
SPECIFICATIONS:
Soap tank capacity (fl oz)
Battery type required
Cover
Battery life estimated
Detection range automatic (inch)
Room temperature (°F)
Sensing delay time (msec)
Dispensing volume (fl oz)
Applicable viscosity range (cps)
Unit net weight empty (oz)
Operation mode
Pump type
USER'S INSTRUCTIONS
1. Place hand below the dispenser spout within the sensing range. The dispenser will automatically release the
preset amount of liquid soap from the nozzle spout.
2. 0btain additional soap by withdrawing hand and then again placing hand below the dispenser spout within the
sensing range.
SENSING RANGE
Sensing is automatically controlled to set the appropriate distance for the triggering zone. This is based upon
mounting height above the counter or floor and the ambient and reflected lighting conditions. There are no user
adjustable controls for this feature.
It is important to observe the guidelines in Section 4 (on reverse side of these instructions) and install unit above the
minimum distance noted for each type of field condition. If lighting conditions change during the life of the installation
the unit will automatically readjust itself to accommodate the new environment with no intervention by owner. Counter
top reflective quality changes constitute a new environment condition and may require dispenser relocation to just
above the appropriate minimum height as below.
IMPORTANT NOTICE
1. Ensure no bright source is aimed or reflected at the sensor from below.
2. Use fresh new liquid soap only and clean the soap container properly before each re-fill. Deposits of old soap will
lead to malfunction and jamming.
3. Do not dilute liquid soap unless concentrate and do not use soap containing abrasive. Observe indicated viscosity
factor of liquid soap.
4. Do not immerse the soap dispenser in water or clean it under running water. This will lead to short circuit.
5. Should the dispenser be out of order and batteries have been replaced, do not attempt any repair work. Call your
dealer for professional assistance.
BATTERY LOW INDICATION
With housing cover open and soap reservoir removed perform the following diagnostic test:
1. Press and push up the cover safety interlock switch on bottom to click and hold it.
2. Observe that the LED is lit blue and then flashes three (3) times indicating proper operation "stand-by" condition
and battery charge level.
3. If LED continues to flash blue the indication is positive to replace the batteries.
32
Alkaline 1,5V C size Qty 3
ABS plastic
100 000 cycles or 1 year
2,40 +/-1,50
41 to 104
500 to 1000
0,033 to 0,050
2000 to 5000
24,6
Automatic from sensor trigger
Self contained valve/nozzle