Dantherm Master XL 61 Manuel D'utilisation Et De Maintenance page 7

Table des Matières

Publicité

►►8. DISPLAY ERRORS
en
See B Fig. 3
it
ERROR
de
F0
1. The "ON/OFF" switch is turned
es
"ON" (|) when the heater is plugged
in
fr
nl
F1
1. No fuel
pt
2. Fuel is contaminated
da
fi
no
3. Photocell is dirty or damaged
sv
4. Fuel filter is dirty
5. Ignition error
pl
ru
F2
1. Interrupted cable
2. Sensor is damaged
cs
hu
F3
1. Internal heater overheating
sl
2. Antitilting sensor intervent
tr
hr
F4
1. Incorrect voltage
lt
lv
FF
1. No fuel
et
2. Dirty fuel filter
3. Dirty or defective photocell
ro
4. Dirty or defective nozzle
sk
5. Anti-tilting sensor trip
bg
[ ]
1. Thermostat connected
uk
2. Switching from cable to battery
bs
power supply
el
zh
CAUSE
OPERATION ERROR
PHOTOCELL ERROR
TEMPERATURE CONTROL SENSOR ERROR
THERMOSTAT ERROR
INCORRECT VOLTAGE
NO SWITCH-ON AFTER THREE ATTEMPTS
HEATER IN STAND-BY
SOLUTION
1. After disconnecting the heater, see that
the switch is in the "OFF" (0) position,
plug the heater in and turn the switch
"ON" (|)
1. Turn the switch "OFF" (0), refill the fuel
tank
2. Turn the switch "OFF" (0) empty and
refill the fuel tank. Clean the filter using
clean fuel, do not damage the filter (SEE
PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Contact the technical service center
2. Contact the technical service center
1. Turn the heater off, wait until it is cooled
down
2. Place the heater on a level and stable
surface
1. Check voltage of your electric supply
system
1. Contact the technical service center
2. Contact the technical service center
3. Contact the technical service center
4. Contact the technical service center
5. Contact the technical service center
1. Thermostat temperature set below the
room temperature
2. Automatic re-ignition

Publicité

Table des Matières
loading

Table des Matières