Technical Specifications - Cash Acme TANK BOOSTER HEATGUARD 020 Série Directives D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Technical Specifications:

Pre-set outlet temperature :
Outlet temperature range :
Temperature, hot supply :
Temperature, cold supply :
Temperature stability (nominal) :
Hydrostatic pressure :
Permitted supply pressure variation :
Flow rate @ 45psi pressure loss :
Flow rate, minimum :
Notes :
1.
As tested in accordance with ASSE1017.
2.
Maximum permitted variation in either supply pressure in order to
control the outlet temperature to within ±5°F. Excessive changes in supply
pressures may cause changes in outlet temperature.
California Proposition 65 Warning
Warning: This product contains chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm. (Installer:
California law requires that this warning be given to the consumer.)
TANK BOOSTER
Installation Instructions/ Directives d'Installation/ Instrucciones de Instalación
IS279 REV K
11-12-12
115 – 120°F (46 – 49°C)
90 – 130 F (32 – 54°C)
195°F max (90°C)
39 - 80°F (5 – 27°C)
1
± 5 F
(± 3 C)
150 psi max (1030 kPa)
3
±20%
11 gpm (42 L/min)
1 gpm (4 L/min)

Publicité

Table des Matières
loading

Table des Matières