5.
Using a thermometer, test the mixed water temperature at
the nearest outlet being supplied by the valve. This should
The thermo-strip included in this kit may be used to indicate the outlet
temperature of the mixing valve to the household.
It shall not be used to set the outlet temperature of the mixing device; this
must be performed as stated in the temperature setting instructions.
To install the thermo-strip, remove the adhesive backing and apply the
thermo-strip to the mixing valve outlet pipe-work no less than 10" from the
outlet connection.
For the thermo-strip to operate correctly it must only be installed on
copper or galvanised tube.
TANK BOOSTER
Installation Instructions/ Directives d'Installation/ Instrucciones de Instalación
IS279 REV K
11-12-12
Thermo-strip
be opened to allow a
minimum flow rate of 1.5
gpm (6 L/min). Allow the
water to run for at least
one minute to ensure
the
mixed
temperature has settled.
water