Philips 1200 Série Mode D'emploi page 18

Masquer les pouces Voir aussi pour 1200 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 77
English
20
Problem
The 'empty coffee
grounds container' light
remains on.
The machine prompts to
empty the coffee
grounds container even
though the container is
not full.
The coffee grounds
container is too full and
the 'empty coffee
grounds container' light
did not go on.
I cannot remove the
brew group.
I cannot insert the brew
group.
The coffee is watery.
Cause
You emptied the coffee grounds
container while the machine
was switched off.
The machine did not reset the
counter the last time you
emptied the coffee grounds
container.
You removed the drip tray
without emptying the grounds
container.
The brew group is not in the
correct position.
The brew group is not in the
correct position.
The brew group is dirty or needs
to be lubricated.
Solution
Always empty the coffee grounds
container while the machine is switched
on. Remove the coffee grounds
container, wait at least 5 sec. and then
insert it again.
Always wait approx. 5 seconds when
you place back the coffee grounds
container. In this way the coffee
grounds counter will be reset to zero.
Always empty the coffee grounds
container while the machine is switched
on. If you empty the coffee grounds
container when the machine is switched
off, the coffee grounds counter won't
reset.
When you remove the drip tray, also
empty the coffee grounds container
even if it contains only a few coffee
pucks. In this way the coffee grounds
counter will be reset to zero, re-starting
to correctly count the coffee pucks.
Reset the machine in the following way:
close the service door and place back
the water tank. Switch the machine off
and back on again. Try again to remove
the brew group. See chapter 'Removing
and inserting the brew group' for step
by step instructions.
Reset the machine in the following way:
close the service door and place back
the water tank. Leave the brew group
out. Switch the machine off and unplug
it. Wait for 30 sec. and then plug the
machine back in and switch it on. Then
put the brew group in the correct
position and reinsert it into in the
machine. See chapter 'Removing and
inserting the brew group' for step by
step instructions.
Remove the brew group (see 'Removing
the brew group from the machine'),
rinse it under the tap and leave it to dry.
Then lubricate the moving parts (see
'Lubricating the brew group').