Troubleshooting Guide - Pattfield Ergo Tools E-HA 6036 Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Anleitung_E_HA_6036_SPK7__ 28.11.13 08:46 Seite 12
GB

11. Troubleshooting guide

Faults
Motor fails to start up
No intake
Inadequate delivery rate
Thermostat switches pump off
12
Cause
- No mains voltage
- Pump rotor blocked -thermostat
switched off
- Pump chamber without water
connection
- Air in intake line air-tight
- Max. suction height exceeded
- Suction height too high
- Strainer dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Motor overloaded - friction
caused by foreign substances
too high
Remedy
- Check voltage
- Dismantle and clean pump
- Fill water into intake
- Make sure intake line is close
- Check suction height
- Check suction height
- clean
- Place the suction hose at a
deeper level
- Clean pump and replace wearing
- Dismantle and clean pump.
Prevent intake of foreign
substances (filter)

Publicité