NOTE: Optional blower motor rear-mounting position
(opposite side) for island cabinet locations. The blower motor
box assembly can be moved to the opposite side (rear)
of the vent box.
1. Remove 7 screws from the mounting flanges of the blower
motor box.
Front View
A
C
A. Screws (7)
B. Keyhole slot shoulder screws (2)
C. Blower motor box
A
A. Blower motor box
2. Lift blower motor box off the shoulder screws in the keyhole
slots. Disconnect wire connection from blower motor and set
blower motor box aside.
3. Remove 6 screws from the mounting flange of the ¼" (6.4 mm)
deep cover.
12
Rear Mounting – Blower Motor
A
A
B
Rear View
C
A. Screws (6)
B. Keyhole slot shoulder screws (2)
C.
/
" (6.4 mm) deep cover
1
4
A. Deep cover
4. Lift the ¼" (6.4 mm) deep cover off the shoulder screws
in the keyhole slots and set the cover aside.
5. Remove the screws from the wire-mounting plate.
A
B
A. Screws
B. Wire-mounting plate
C. Blower motor box
A
B
A
A
C