X. TROUBLESHOOTING
Start-up of the device
•
Make sure the flow controller is put into position 1 (wheel with measurements)..
No suction
•
The pump has sucked in particles, the valves allow the liquid to flow through but
suction is not possible. To remove these particles, you need to place the tube in
a higher vessel and boot the device to fill the pump and clean the device.
•
Lack of power
Make sure the battery is fully charged.
Check and clean the nozzle and filter, which could be clogged.
•
Irregular jet
Check and clean the nozzle which may be clogged. The filter of the filter
cartridge may be clogged.
•
Leaks
Check the seals and whether the nozzle is sufficiently tightened.
•
Inflexibility of the suction tube
When the ambient temperature is too low, suck up hot water to soften the hose.
XI. TECHNICAL SPECIFICATIONS, REGULATIONS AND WARRANTY
-
Diaphragm pump (diaphragm and valves in RESISTENT MATERIALS)
-
Adjustable flow rate of 0.85 to 1.70 l / min, depending on the used nozzle
-
Pressure: 7 bar
-
Electronic security 'overdischarge' (battery protection)
-
Non-stop use up to 2.5 to 3 hours depending on the type of work
-
Lithium battery 14.4 volt 2.2 Ah (type Bosch)
-
Charging time 1 hour, depending on the charge status of the battery
-
Input voltage: 90 to 230 VAC 50/60 Hz
-
Output voltage: 16.80 VDC 1.3 A
-
Temperature range: 0 to 45°
-
Dimensions of the carton 26 x 9 x 60 cm - weight: 4.3 kg
| 41