Mounting the hood body
• Open the ducting panels.
• Disconnect the panel from the hood canopy by slid-
ing the fixing pin lever.(A)
• Remove the metal grease filters by turning the han-
dles provided.
• Adjust the two screws Vr, on brackets 11a, to a mini-
mum.(B)
• Hook the hood canopy onto the two brackets 11a.
• From inside the hood canopy, adjust the screws Vr to
set the Hood Canopy level.
• Tighten the safety screw 11.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe the
choice of which is left to the installer.
To install a ø 150
• To install the dumper 10 ø 150.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
To install the Recirculation Version of the hood, the
optional Activated charcoal cartridge kit must be pur-
chased.
• Screw the filter cover onto the air outlet, using four
screws 12c (2.9 x 12.5).
• Fix the directional grille 8 on the recirculation air
outlet using the 2 screws 12d (2,9 x 9,5) provided.
EN
Connections
Vr
( B )
( A )
ø 150
10
8
16
12d
12c
1
17
7