Erie SLIMLINE SLI-WHF Série Instructions D'installation Et D'emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
HOLIDAY MODE
It is possible to put the appliance in holiday mode; this will
prevent automatic regeneration from taking place, yet will
ensure the appliance is automatically regenerated at the end
of the holiday cycle.
1. Press the scroll
button repeatedly until the display
shows:
Holiday: OFF
Press the up
or down
holiday mode by setting the number of full days away
from home, or deactivate the holiday mode (OFF).
Once the control panel is back in service mode, the display
will show:
8:01
Holiday
The holiday mode is automatically cancelled when a
regeneration is manually initiated!
ELECTRONIC CONTROL PANEL
button to activate the
Page 9
PROGRAMMING INSTRUCTIONS -
BASIC SETTINGS
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
button and hold it for 2 sec until the
display shows:
Language:English
Press the up
or down
language.
2. Press the scroll
button again; the display will show:
Set time:
Press the up
or down
day.
3. Press the scroll
button again; the display will show:
Interval:7 Days
Press the up
or down
of days between regenerations.
4. Press the scroll
button again; the display will show:
Buzzer: ON
Press the up
or down
disable the buzzer.
5. Press the scroll
button again; the display will show:
Exit
Press the up
or down
into the NOVRAM® and exit the programming mode.
The regeneration cycle is necessary to wash out
impurities that are captured in the filter media during the
service cycle, and to prevent 'caking' of the filter media,
which may result in an increase of pressure drop over the
appliance. Typically a regeneration every 7 days should be
sufficient. In case of high flow rates, excessive water usage
or a high concentration of impurities in the incoming water,
it may be necessary to lower the number of days between
regenerations.
button to set the
8:01
button to set the time of
button to set the number
button to enable or
button to save the settings