Information about the device
Description of the device
Channel extension
• 2 channels
• Duration ON / Duration OFF / Override /
Automatic mode
• Communication between the channel
extension, timer, and LAN module takes
place via Powerline Communication
(PLC)
Designated use
• Channel extension for timers
• Mounting only on DIN rail
• Suitable for use in dry rooms only!
• Do not install in the vicinity of devices
having inductive discharges (motors,
transformers, etc )
12
Technical data
Dimensions Hx W x D (mm)
Weight g (approx )
Main voltage
Protection class
Power consumption
Switching capacity
– Ohmic load (VDE, IEC)
– Inductive load cos φ 0 6
– Glow/halogen lamp load
– Fluorescent light
– Max switching power AC1
/ AC15
Switching contacts
Ambient temperature
Switching state display
Sealable
45 x 35 x 60
140
See rating plate
||
5 VA
16 A / 250 V AC
10 A / 250 V AC
2600W
1000W
3700W /
750W
2 change-over contacts
-10°C + 55°C
Yes
Yes