Tableau 24 : Combinaisons de vitesses de liaison prises en charge
Port1 Link Speed
Setting
Forced 1G
Forced 10G
Forced 1G
P1: no AN
P1: no AN
P2: no AN
P2: no AN
Forced 10G
P1: no AN
P1: no AN
P2: no AN
P2: no AN
Forced 25G
P1: no AN
Not supported
P2: no AN
AN Enabled
P1: {1G}
P1: {1G}
{1G}
P2: no AN
P2: no AN
AN Enabled
P1: AN {10G}
P1: AN {25G}
{10G}
P2: no AN
P2: no AN
AN Enabled
P1: AN {25G}
Not supported
{25G}
P2: no AN
AN Enabled
P1: AN {1/10G} P1: AN {1/10G} P1: AN {1G}
{1/10G}
P2: no AN
P2: no AN
AN Enabled
P1: AN {1/25G} P1: {1G}
{1/25G}
P2: no AN
P2: no AN
AN Enabled
P1: AN {10/
P1: {10G}
{10/25G}
25G}
P2: no AN
P2: no AN
AN Enabled
P1: AN {1/10/
P1: {1/10G}
{1/10/25G}
25G}
P2: no AN
P2: no AN
Remarque : Utilisez un émetteur-récepteur optique pris en charge ou un câble en cuivre d'attache
directe pour atteindre la vitesse de liaison 1 Gbit/s.
•
P1 : configuration port 1
•
P2 : configuration port 2
•
AN : négociation automatique
•
No AN : vitesse forcée
26 février 2018 • NetXtreme-E-UG100
AN Enabled
Forced 25G
AN Enabled {1G}
{10G}
P1: no AN
P1: no AN
P1: no AN
P2: no AN
P2: {1G}
P2: AN {10G}
Not supported
P1: no AN
P1: no AN
P2: {1G}
P2: {10G}
P1: no AN
P1: no AN
P1: no AN
P2: no AN
P2: no AN
P2: no AN
P1: {1G}
P1: AN {1G}
P1: AN {1G}
P2: no AN
P2: AN {1G}
P2: AN {10G}
Not supported
P1: AN {10G}
P1: AN {10G}
P2: AN {1G}
P2: AN {10G}
P1: AN {25G}
P1: AN {25G}
Not supported
P2: no AN
P2: AN {1G}
P1: AN {1/10G}
P1: AN {1/10G}
P2: no AN
P2: AN {1G}
P2: AN {10G}
P1: AN {1/25G} P1: AN {1/25G}
P1: AN {1G}
P2: no AN
P2: AN {1G}
P2: AN {10G}
P1: AN {25G}
P1: AN {10/25G}
P1: AN {10G}
P2: no AN
P2: AN {1G}
P2: AN {10G}
P1: AN {1/25G} P1: AN {1/10/
P1: AN {1/10G}
25G}
P2: no AN
P2: AN {1G}
P2: AN {10G}
Port 2 Link Setting
AN Enabled
AN Enabled {1/
{25G}
10G}
P1: no AN
P1: no AN
P2: AN {25G}
P2: AN {1/10G}
Not supported
P1: no AN
P2: AN {1/10G}
P1: no AN
P1: no AN
P2: no AN
P2: AN {1G}
P1: AN {1G}
P1: AN {1G}
P2: AN {25G}
P2: AN {1/10G}
Not supported
P1: AN {25G}
P2: AN {1G}
P1: AN {25G}
P1: AN {1/10G}
P2: AN {25G}
P2: AN {1/10G}
P1: AN {1/10G}
P1: AN {1/25G}
P2: AN {25G}
P2: AN {1/10G}
P1: AN {1/25G}
P1: AN {10/25G}
P2: AN {25G}
P2: AN {1/10G}
P1: AN {25G}
P1: AN {1/10/25G}
P2: AN {25G}
P2: AN {1/10G}
P1: AN {1/25G}
P1: AN {1/10/25G}
P2: AN {25G}
P2: AN {1/10G}
Configuration au niveau du système
AN Enabled {1/
AN Enabled {10/
AN Enabled {1/10/
25G}
25G}
25G}
P1: no AN
P1: no AN
P1: no AN
P2: AN {1/25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
P1: no AN
P1: no AN
P1: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {1/10G}
P1: no AN
P1: no AN
P1: no AN
P2: AN {1/25G}
P2: AN {25G}
P2: AN {1/25G}
P1: AN {1G}
P1: AN {1G}
P1: AN {1G}
P2: AN {1/25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
P1: AN {10G}
P1: AN {10G}
P1: AN {10G}
P2: AN {1G}
P2: AN {10G}
P2: AN {1/10G}
P1: AN {25G}
P1: AN {25G}
P1: AN {25G}
P2: AN {1/25G}
P2: AN {25G}
P2: AN {1/25G}
P1: AN {1G}
P1: AN {1/10G}
P1: AN {1/10G}
P2: AN {1G}
P2: AN {10G}
P2: AN {1/10G}
P1: AN {1/25G}
P1: AN {1/25G}
P1: AN {1/25G}
P2: AN {1/25G}
P2: AN {25G}
P2: AN {1/25G}
P1: AN {25G}
P1: AN {10/25G}
P1: AN {10/25G}
P2: AN {25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
P1: AN {1/25G}
P1: AN {1/10/25G} P1: AN {1/10/25G}
P2: AN {1/25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
Page 42