5. Attach the air hose to the relocated air inlet fitting.
NOTE: In bleeder setup, the removal of the air flow
adjustment knob causes the air supply to be
on at all times when the air hose is attached
to the gun.
Choosing a Projector Set
Your HVLP spray gun should be fitted with the proper projector
set for the type of work you will be performing. A projector set
consists of a needle assembly, a fluid nozzle, and an air cap.
Needle Assembly
Fluid Nozzle
You should choose a projector set based on two things: the
type of material to be sprayed and the finish desired.
The chart on the following page should help you to make the
right choice.
Changing a Projector Set
1. Remove the air cap ring, air cap, and spring plate.
2. Remove the fluid nozzle.
© SprayTECH. All rights reserved.
Air Cap
Air Cap Ring
Air Cap
Spring Plate
3. Remove the material flow adjustment knob and spring.
Material Flow Adjustment Knob
Spring
4. Remove the needle.
CAUTION
If the needle does not slide out easily, loosen the packing
nut to prevent the needle or packing from being damaged.
5. Install the new projector set in reverse order.
9
English